DC-DC Power Modules
Customized DC-DC Converters Explore DC-DC ConvertersAccessory name/model | Dimensions | Application |
| It is suitable for analog output sensor, and can set the starting position and full range point of analog output displacement sensor Includes: handheld programmer, 220V power supply, sensor adapter × 2 | |
Interface converter Order No.:TEC612802 | Applicable to SSI output sensor, the digital tube displays the displacement value of the output vernier magnet ring in real time. Includes: interface converter, 220V power supply, sensor adapter cable × 2 | |
USB dongle Order No.:TEC612811 | Applicable to analog output sensor, PC is connected with sensor through USB port, and TEC sensor configuration software is used for programming: 1) setting sensor measuring direction; 2) Setting sensor zero point and full-scale point; 3) Graphical display of magnet ring position value; 4) Diagnosing sensor online through error code. Includes: USB converter, USB data cable, sensor adapter × 2, software | |
USB dongle Order No.:TEC612812 | Suitable for SSI output sensor, through USB port to connect PC and sensor, using TEC sensor configuration software for programming: 1) Set sensor parameters (data length, data format, measuring direction); 2) Graphic display of magnet ring position value; 3) Users arbitrarily set sensor zero point and measuring display value; 4) On-line diagnosis of sensor through error code. Includes: USB converter, USB data cable, sensor adapter × 2, software |
Model | Effective Stroke | Interface | Voltage | Nonlinearity | Repeatability | Updated on | Protection Grade |
Operation Temperature (℃) |
Material | Shock| Pressure | Datasheet | Sample |
ESC Analog Seris | 50–3000 mm | 4-20mA or 20-4mA | 0~10Vdc or 0~5Vdc | 士0.1mm(25~400mm) | <±0.l mm | lms (four wire system)/ 100 ms (two wire system) | IP67 | -40°C ~ +75°C | PFA | GB/T2423.5 50g(6ms) | ![]() |
|
EP Analog Seris | 25-5500 mm | 0-20mA or 4-20mA | 0~10Vdc or 0~5Vdc | 0.05% F.S | < 0.03% of full scale | < 0.005% of full scale | IP65 | -40°C ~ +85°C | Aluminum formed shell | GB/T2423.5 50g(6ms) | ![]() |
|
ED Analog Seris | 50–3000 mm | / | 0–10V/10–0V, signal/ dual | <±0.05% of full scale | <± 0.01% of full scale | 2MS | IP65 | -40°C ~ +75°C | Aluminum Alloy | GB/T2423.5 50g(11ms) , 5 g,10–2000 Hz GB/T2423.10 | ![]() |
|
![]() |
||||||||||||
![]() |
||||||||||||
![]() |
||||||||||||
![]() |
||||||||||||
EJ SSI Output Seris | 25-5500 mm | 4-20mA or 0-20mA | 0-10Vdc or 0-5Vdc | <+0.02% of full scale | <± 0.001% offull scale | lms | Outgoing line lP68, Socket LP67 | -40°C - +75°C | 304L/316L stainless steel | GB/T2423.5 50g(6ms) , 35MPA/70MPA(peak) | ![]() |
|
EJ Modbus Seris | 25-5500 mm | 4-20mA or 0-20mA | 0-10Vdc or 0-5Vdc | <+0.02% of full scale | <± 0.001% offull scale | lms | Outgoing line lP68, Socket LP67 | -40°C - +75°C | 304L/316L stainless steel | GB/T2423.5 50g(6ms) , 35MPA/70MPA(peak) | ![]() |
|
EJ Analog Seris | 25-5500 mm | 4-20mA or 0-20mA | 0-10Vdc or 0-5Vdc | <+0.02% of full scale | <± 0.001% offull scale | lms | Outgoing line lP68, Socket LP67 | -40°C - +75°C | 304L/316L stainless steel | GB/T2423.5 50g(6ms), 35MPA/70MPA(peak) | ![]() |